6. Commissioning
6.1 Preparation of Commissioning
Ensure all the devices are accessible for operation, maintenance and service.
Check and confirm that the inverter is firmly installed.
Space for ventilation is sufficient for one inverter or multiple inverters.
Nothing is left on the top of the inverter or battery module.
Inverter and accessories are correctly connected.
Cables are routed in safe place or protected against mechanical damage.
Warning signs and labels are suitably affixed and durable.
7. Maintenance
6.2 Commissioning Procedure
If all the items mentioned above meet the requirements, proceed as follows to start up
the inverter for the first time.
6.3 Shutdown procedure
1. Turn off the AC isolator at the grid connection point.
2. Turn off the DC switch of the inverter.
3. Turn off the DC switch between inverter and battery.
4. Waiting for the LCD of inverter to turn off and the system shutdown is completed.
1. Switch on the AC-backup and AC-grid.
2. Select grid standard.
3. Congure the parameters.
4. Before switching on the Inverter DC switch, turn on the battery DC switch and verify
polarity.
5. Turn on the Inverter DC Switch.
6. Verify inverter initializes.
Note:
Never use any solvents, abrasives or corrosive materials to clean the inverter.
CAUTION:
Do not touch the surface when the inverter is operating. Some parts may be hot
and cause burns. Turn OFF the inverter (refer to Section 6.2) and let it cool down
before you do any maintenance or cleaning of inverter.
The LCD and the LED status indicator lights can be cleaned with cloth if they are too dirty
to be read.
Solis RHI-5G Series inverter does not require any regular maintenance. However, cleaning the
heatsink will help inverter dissipating heat and increase the lifetime of inverter. The dirt on the
inverter can be cleaned with a soft brush.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS RHI-5G Series and is the answer not in the manual?

SOLIS RHI-5G Series Specifications

General IconGeneral
TypeHybrid Inverter
Max DC Voltage600 V
Max DC Input Power6500 W
Nominal AC Output Power5000 W
Max AC Output Power5500 W
Number of MPPTs2
Battery Voltage Range40-60V
Max Charge/Discharge Current100 A
Protection DegreeIP65
Frequency50/60 Hz
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
ModelRHI-5G
Rated Power Output5kW
MPPT Voltage Range90 V - 520 V
Efficiency97.6%
Communication InterfacesRS485, WiFi
Nominal AC Voltage230V