EasyManuals Logo

SOLIS S5-EH1P-L User Manual

SOLIS S5-EH1P-L
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
6. Operation 6. Operation
.50..49.
6.4 Settings
In the "Settings" section, Time/Date, Slave address and language can be modified.
Figure 6.9 Setting
Settings
Settings
2015-02-23 19 35
Set Time/Date
Set Address
Set Language
6.4.1 Set Time/Date
Figure 6.10 Set Time
Set Time/Date
2015-02-23 19 35
N E X T =< E N T > D O N E = < E S C >
MM DDYY
2 232015
--
HH MM
20 53
:
E S C
U P
D O W N E N T
Set the time and date on the inverter. Must set this according to local time as it
affects the daily yield calculation. (If Solis monitoring system is used, must set
the correct time zone of the system, otherwise datalogger will update the inverter
time based on the time zone of the system.)
Press "UP" and "DOWN" to change the value.
Press "ENT" to mover the cursor.
Press "ESC" to save the change.
6.4.2 Set Address
Set the slave address of the inverter. The default address is 01.
Figure 6.11 Set Address
Settings
Set Address
2015-02-23 19 35
Y E S = < E N T > N O = < E S C >
Slave Address01
E S C
U P
D O W N E N T
6.4.3 Set Language
Set system language. Chinese and English are available.
Settings
Figure 6.12 Set Language
Set Language
2015-02-23 19 35
English
Y E S = < E N T > N O = < E S C >
E S C
U P
D O W N E N T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5-EH1P-L and is the answer not in the manual?

SOLIS S5-EH1P-L Specifications

General IconGeneral
BrandSOLIS
ModelS5-EH1P-L
CategoryInverter
LanguageEnglish

Related product manuals