8. Troubleshooting
User Manual
Message Name
Reverse-DC
(1028 DATA:0000)
GRID-INTF.
(1030 DATA:0000)
INI-FAULT
(1031 DATA:0000)
OV-TEM
(1032 DATA:0000)
Information Description
Reverse DC polarity
AC hardware overcurrent
Initialization system fault
Over Temperature
Troubleshooting Suggestion
1. Check if the DC line is reversed.
2. Restart the inverter.
3. If it is still not excluded, please contact
the factory customer service.
1. Check whether the AC connection is
virtual.
2. Restart the inverter.
3. If it has not been eliminated, contact the
factory's customer service.
1. Restart the inverter.
2. If it is still not resolved, contact the
factory's customer service.
1. Check whether the inverter installation
position meets the requirements of the
user manual.
2. Try to reduce the ambient temperature.
3. Restart the inverter after fifteen minutes.
4. If the error persists, please contact the
factory's customer service.
1. Check whether the PV strings have
insulation problems.
2. Check whether the PV cable is damaged.
36
PV Isolation Protection 02
(1033 DATA:0002)
PV negative ground fault
PV Isolation Protection 01
(1033 DATA:0001)
DC bus undervoltage
1. Connect each string component
individually to determine if it is caused
by a component problem. If there is no
error when inserting one of the string
components, it can be determined that it
is a string problem. Check whether the
string in question is broken or not.
2. If this error is only caused by a rainy day
or a certain time of the morning, it is
because the aging of the module causes
the leakage current to be too large.
When the weather is fine or the air
humidity is reduced, the error will be
cleared automatically. Can be resolved
through remote upgrade software.
Leakage Current
Protection 01
(1034 DATA:0001)
Leakage current
protection
Leakage Current
Protection 02
(1034 DATA:0002)
Leakage Current
Protection 03
(1034 DATA:0003)
Leakage Current
Protection 04
(1034 DATA:0004)