9.2 Hyper 3680/4600/5000
PV Inputs
Hyper 3680
Hyper 4600
Hyper 5000
Max. PV-generator power
4000VA
5400VA
5400VA
Max. PV voltage
550V d.c.
Rated PV Voltage
360V d.c.
MPPT Voltage Range
125~500V d.c.
PV Start Voltage
100V d.c.
Max. PV current
10A/10A d.c.
Max. Short Circuit Current
14A/14A d.c.
Strings per MPP Tracker
1
Number of MPP Trackers
2
Galvanic Isolation for PV
Modules
Transformerless
Reverse Current to PV Panels
No
AC Ratings
Hyper 3680
Hyper 4600
Hyper 5000
Rated AC Power
3680VA
4600VA
5000VA
Rated AC Voltage
230V a.c.
AC Voltage Range
180V~264V a.c.
Rated AC Frequency
50Hz/60Hz
Max. AC Current to Grid
(Feed Back Current)
16A a.c.
20A a.c.
21.7A a.c.
Max. AC Current from Grid
(Bypass + Grid Charge)
30A a.c.
30A a.c.
30A a.c.
Max. Output Overcurrent
Protection
40A a.c.
40A a.c.
40A a.c.
Power Factor Range
-0.8~+0.8
Total Harmonic Distortions (i)
<3%
Inrush Current
(Peak/Duration)
120A/32us
Max. Output Fault Current
(Peak/Duration)
200A/10ms
EPS Ratings
Hyper 3680
Hyper 4600
Hyper 5000
EPS Rated Power
4000VA
5000VA
5000VA
Overload Capacity
1.1 x Pnom, 10 sec; 1.5 x Pnom, 100 ms
EPS Rated Voltage
230V a.c.
EPS Rated Frequency
50Hz/60Hz
EPS Rated Current
17.4A
21.7A
21.7A
Changeover Time
2s in EPS Mode, 10ms in UPS Mode
Total Harmonic Distortion (V)
< 3%
Parallel Operation
No
Battery Ratings
Hyper 3680
Hyper 4600
Hyper 5000
Battery Type
Lithium
Rated Battery Voltage
48V d.c.
Battery Voltage Range
40~60V d.c.