– 22 –
Notes:
1. CD block basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise
indicated.
3. Use the oscilloscope with more than 10 M impedance.
4. Clean an object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
Procedure:
1. Connect the oscilloscope to TP (FE) and TP (VC) on SERVO
board.
2. Connect the TP (FEI: IC101 pin ) and TP (VC) with lead
wire.
3. Turned power switch on.
4. Put disc (YEDS-18) in and turned power switch on again and
actuate the focus search. (actuate the focus search when disc
table is moving in and out.)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within
3.0 ± 1.0 Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note: Try to measure several times to make sure that the ratio
of A : B or B : A is more than 10 : 7.
Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Connection:
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on SERVO
board.
2. Turned power switch on. (stop mode)
3. Put disc (YEDS-18) in and press the ( button.
4. Confirm that the oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape “” can
be clearly distinguished at the center of the waveform.
RF signal waveform
SECTION 5
ELECTRICAL ADJUSTMENTS
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(with the 10: 1 probe
in use)
level: 1.2 Vp-p
+0.25
–0.20
A
B
symmetry
within 3.0 ± 1.0 Vp-p
S-Curve Check
Connection:
+
SERVO board
TP (FE)
TP (VC)
oscilloscope
+
SERVO board
TP (RF)
TP (VC)
oscilloscope
(AC range)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
E-F Balance (Traverse) Check
Connection:
Procedure:
1. Connect the TP1 (ADJ) to ground and TP (TEI: IC101 pin )
to TP (VC) with lead wire.
2. Connect the oscilloscope to TP (TE) and TP (VC) on SERVO
board.
3. Turned power switch on.
4. Put disc (YEDS-18) in and press the ( button.
5. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 Vdc, and check this level.
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency Check
Connection:
Traverse waveform
A
B
+
SERVO board
TP (TE)
TP (VC)
oscilloscope
(DC range)
level: 200 ± 100 mVp-p
+
TP (PLK)
SERVO board
frequency counter
Procedure:
1. Connect the frquency counter to TP (PLK).
2. Turned power switch on.
3. Put disc (YEDS-18) in and press the ( button.
4. Confirm that the reading on frequency counter is 4.3218 MHz.