43
Setting Simple Connection of AUX Bus Remote Panel
Preparation
Setting Simple
Connection of AUX Bus
Remote Panel
Connecting the MKS-8080/8082 AUX Bus Remote Panel
to the control panel using an S-Bus data link normally
requires an HKSP-R80 Routing Switcher Controller Board
or similar primary station and various connection settings.
However, using a simple connection, the MKS-8080/8082
can be connected directly without the need for an S-Bus
data link primary station.
A simple connection is possible if the following conditions
are satisfied.
There are no devices other than the control panel and
MKS-8080/8082 connected on the S-Bus data link.
There are no more than 16 MKS-8080/8082 units
connected on the S-Bus data link.
For information about the input signals and buses that can
be controlled by the MKS-8080/8082, see “Input/outputs
for MVS-6520/6530/3000A/3000 system assigned to S-Bus
matrix” (1 p. 29).
For details about the setting status of the AUX bus remote
panel for a simple connection, refer to the User’s Guide.
1
Initialize the MKS-8080/8082 settings.
a Press and hold down the [X-HOLD] and [KEY]
buttons (MKS-8080) or the [XPT HOLD] and
[LOCK (CHOP)] buttons (MKS-8082)
simultaneously for five seconds.
After “Reset” is displayed in the preset display
window, the MKS-8080/8082 starts to reboot and
the buttons turn on (button light test).
b With the buttons turned on, press and hold down the
[1] and [2] source selection buttons simultaneously.
Rebooting takes approximately one minute and the
MKS-8080/8082 settings are initialized.
For details about initializing settings, refer to
“Making the Settings with Buttons (Setup Function)
in the MKS-8080/8082 Operation Manual.
2
Set the MKS-8080/8082 station ID.
a Initialize the MKS-8080/8082 using the procedure
in step 1-1.
b With the buttons turned on, press and hold down the
[1], [2], [3], and [4] source selection buttons.
“ID=XXX” is displayed in the preset display
window.
c Press the source selection buttons corresponding to
the station ID you want to set.
Set the station ID in the range 2 to 17.
The station ID is given by the sum of the values of
the source selection buttons that are turned on.
For example, turn on the [1], [2], and [4] source
selection buttons (1 + 2 + 8 = 11) to set “11” for the
station ID.
d Press the [ASSIGN] button (MKS-8080) or the
[ASGN] button (MKS-8082) to apply the setting.
For details about setting the station ID, refer to
“Setting the station number” in “Preparations for the
MKS-8080/8082” in the MKS-8080/8082 Operation
Manual.
3
Set the S-Bus data link primary station role to the
control panel.
Set the STATION ID switches on the front of the
board in the MVS-6520/6530/3000A/3000 SLOT 8 to
001 (switch 1 only to the OPEN position).
Source selection
button
Value when button is
on
11
22
34
48
516
632
764
8128
Switcher processor Board STATION ID switch
MVS-6520/6530/
3000A/3000
CA-85 S3801