1-6. Notes on Service
1-6-1. Actions to Be Taken when Replacing Parts and Boards
Before replacement
The DPR-355 board contains all setting data of the menus (including picture profiles).
Before replacing the DPR-355 board, perform the following procedure to store the setup file in an SxS memory card.
1. Insert the SxS memory card for storing the setup file into the card slot.
Confirm that the SxS memory card icon corresponding to the slot appears on the screen.
When another SxS memory card is selected, switch the display with the SLOT SELECT button.
2. Execute Store with Camera Data of the OTHERS menu.
During replacement
1. When any of the following boards has been replaced, update the firmware.
(Refer to “1-5. Updating the Firmware”)
The firmware programs stored on the following boards are updated collectively.
AU-357 board
DCP-64 board
DPR-355 board
KSW-65 board
KY-706 board
RE-320 board
VPR-124 board
2. When any of the following boards or part has been replaced, make adjustments again.
For the adjustment method, contact your local Sony Sales Office/Service Center.
DCP-64 board
3.5-inch LCD assembly
CMOS block
1-6-2. Actions to Be Taken when the Lens Has Been Replaced
When the lens has been replaced, make the flange-back adjustment. (Refer to Operating Instructions)
1-6-3. Notes on Replacing Onboard Parts
The BI-292/294 boards and parts mounted on the BI-292/294 boards cannot be replaced independently. When the
each board or any part on the board is defective, replace the CMOS block.
Similarly, part-level replacement is not possible for each board. If onboard parts become defective, replace the
board.
1-6-4. Backup Battery
When the backup battery is replaced, the date and time in the internal clock need to be set. Refer to "Setting the Clock"