EasyManua.ls Logo

Sony RMT-D187A - FLD All ON Test; Key Input Display Tests

Sony RMT-D187A
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-5
DVP-NS611HP/NS710H/NS710HP/NS717HP/NS718H/NS718HP/NS728H/NS728HP
2-3-1. FLD All ON
2-3-1-1. Transition Keys in Self Check Mode
Z key and x key on the main unit
T key on the remote commander
2-3-1-2. Operation and display
In this mode, all segments of FLD turn ON.
Example of FLD all ON
2-3-2. Main Unit Key Name Display and Key Code Display
2-3-2-1. Transition Keys in Self Check Mode
Keys on the main unit except keys transited in Self Check Mode
2-3-2-2. Operation and Display
When a key on the main unit is pressed in the Self Check mode, the key code is displayed on the FLD. 'KEY FF' is displayed when
nothing is entered. Also, PLAY, PAUSE, REPEAT segments turn on when a communication error occurred.
Key code display (at input of H key, key code: 0Ah)
At input of faulty voltage
When key is pressed double