Access Limit
This allows you to control which computers can have access to the camera.
Likewise, when using IPv6, security settings can be configured for each network.
Access Limit
Set an access limit to the camera.
Rule
Set rules for the access limit of the camera.
User 1 to 9 User Name Enter a user name between 5 and 16
alphanumeric characters.
Current Password Enter the current password.
New Password Enter a password between 8 and 64
al
phanumeric characters. Your password
should be alphanumeric.
Re-Type
P
assword
To confirm the password, retype the
password that you entered in the [New
Password] box.
Viewer Mode Administrator/
F
ull/Light
Full You can select the viewer mode to be
displayed after authentication when the
viewer is displayed.
[Administrator]: The user can operate all
func
tions including the setting screen in
this mode.
[Full]: The user can operate all functions
o
ther than the setting screen and power.
[Light]: The user can display the live
im
age.
Menu item Detail and setting
va
lue
Initial setting value
of the factory
default setting
Content
Setting On/Off Off Enables the access limit.
Menu item Detail and
se
tting value
Initial setting value
of the factory
default setting
Content
Default Policy Allow/Deny Deny Select the basic policy of the limit from
[A
llow] and [Deny] for the computers with
the network address that are not specified
in the [Network Address/Subnet 1] to
[Network Address/Subnet 10] menus
below.
Menu item Detail and
se
tting value
Initial setting value
of the factory
default setting
Content