Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-176-
P08.23
Number of
decimal points of
frequency
0: Two decimal points
1: One decimal point
0
P08.24
Number of
decimal points of
linear speed
0: No decimal point
1: One
2: Two
3: Three
0
P08.25
Set count value
P08.2665535
0
P08.26
Designated count
value
0–P08.25
0
P08.27
Set running time
0–65535min
0min
P08.28
Automatic fault
reset times
Automatic fault reset times: When the VFD selects
automatic fault reset, it is used to set the times of
automatic reset, if the continuous reset times exceeds
the value set by P08.29, the VFD will report fault and
stop to wait for repair.
Interval of automatic fault reset: select the interval time
from when fault occurred to automatic fault reset actions.
After VFD starts, if no fault occurred during 60s, the fault
reset times will be zeroed out.
Setting range of P08.28: 010
Setting range of P08.29: 0.1–3600.0s
0
P08.29
Automatic fault
reset time interval
1.0s
P08.30
Reduction ratio of
droop control
This function code sets the variation rate of the VFD
output frequency based on the load; it is mainly used in
balancing the power when multiple motors drive the
same load.
Setting range: 0.00–50.00Hz
0.00Hz
P08.31
Switch-over
between motor 1
and motor 2
0x000x14
Ones: Switch-over channel
0: Switch over by terminal
1: Switch over by Modbus/Modbus TCP communication
2: Switch over by PROFIBUS/CANopen/DeviceNet
3: Switch over by Ethernet communication
4: Switch over by EtherCAT/PROFITNET/Ethernet IP
communication
Tens: Motor switch over during running
0: Disable switch over during running
1: Enable switch over during running
0x00
P08.32
FDT1 level
detection value
When the output frequency exceeds the corresponding
frequency of FDT level, multi-function digital output
terminal outputs "frequency level detection FDT" signal,
this signal will be valid until the output frequency lowers
to below the corresponding frequency (FDT level-FDT
lag detection value), the waveform is shown in the figure
below.
50.00Hz
P08.33
FDT1 lag
detection value
5.0%
P08.34
FDT2 level
detection value
50.00Hz
P08.35
FDT2 lag
detection value
5.0%