SPECTRA SERIES 15
PART 3: PROGRAMMING METHODS
3.1 WINLOAD SOFTWARE FOR WINDOWS
Program the Spectra Series control panels remotely or on-site using the Winload Software for Windows®. For more
information, contact your local Paradox Distributor or visit our web site at http://www.paradox.ca. If you are using the
WinLoad software, you must program the features explained on pages 45 to 46.
3.2 PROGRAMMING USING A KEYPAD
Use the supplied "Spectra Programming Guide" to keep track of which sections were programmed and how. We
recommend you read this entire manual before you begin programming.
3.2.1 SINGLE DIGIT DATA ENTRY METHOD (HEXADECIMAL AND DECIMAL)
Single Digit Data Entry is used in all sections except those specified in Multiple Feature Select Programming
Method. After entering the programming mode as described in the shaded box above, some sections will
require that you enter
Decimal
values from
000 to 255
. Other sections will require that you enter
Hexadecimal
values from
0 to F
. The required data will be clearly indicated in this manual as well as in the Spectra Series
Programming Guide. When entering the final digit in a section, the control panel will automatically save and
advance to the next section. With the exception of sections 001 to 016, where after entering the first two digits,
the control panel will switch to Multiple Feature Select Programming.
3.2.2 M
ULTIPLE
F
EATURE
S
ELECT
P
ROGRAMMING
M
ETHOD
Sections: [001] to [016], [127] to [138], [302] to [348], [610], [650] to [651]
After entering the programming mode as described in the shaded box above, each option from
[1]
to
[8]
will
represent a specific feature or option. Press the key corresponding to the desired option and the
corresponding light will illuminate or the option number will appear in the LCD display. This means the option is
on. Press the key again to extinguish the corresponding light or remove the digit from the LCD display, thereby,
turning off the option. Please note that pressing the
[
FORCE
]
key will set all 8 options to “off”. Press the keys as
many times as you need until all 8 options in the current section are set. When the options are set, press the
[
ENTER
]
key to save and advance to the next section.
How Do I Enter Programming Mode?
STEP 1: Press
[
ENTER
]
STEP 2: Enter your
[
INSTALLER
CODE
]
(default: 000000)
STEP 3: Enter 3-digit
[
SECTION
]
you wish to program
STEP 4: Enter required
[
DATA
]
Table 3: Decimal and Hexadecimal Programming Table
Value or Action What Do I
Press?
What Do I See?
10-Zone LED 16-Zone LED LCD
Values 1 to 9 [1] to [9] [1] to [9] [1] to [9] [1] to [9]
A
(hexa only)
[0] [0
(10)
][10] A
B
(hexa only)
[
STAY
][
STAY
][11] B
C
(hexa only)
[
BYP
][
BYP
][12] C
D
(hexa only)
[
MEM
][
MEM
][13] D
E
(hexa only)
[
TBL
] / [
TRBL
][
TBL
][14] E
F
(hexa only)
[
PG
] / [
FNC
1] [
PG
][15] F
Insert Blank Digit [
FORCE
] Displays next digit or next section
Exit Without Saving [
CLEAR
][
ENTER
] flashes [
ARM
1
] & [
STAY
1
] flash SECTION [ ]”
Save Data
(hexa only)
[
ENTER
] Advances to the next section