PART 1: INTRODUCTION
1.1 FEATURES
Up to 16 fully programmable zones:
1725EX: 4 zones [8 zones with ATZ (1725 only)] + 2 keypad zones, can expand to 16 zones
1728EX or 1758EX:5 zones [10 zones with ATZ (1728/1758 only)] + 2 keypad zones, can expand to 16 zones
Up to 8 remote controls built-in with 1758 and 1758EX only.
Two completely independent partitions. Many of the features and options in the Spectra System can be inde-
pendently set for each partition such as event reporting, entry/exit delay, auto-arming and many more. All zones,
the keyswitch and all user codes are assigned to specific partitions, making this a true partitioned system.
Communication bus facilitates the addition, programming and monitoring of wireless and/or hardwire expansion modules.
1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
One or more fully programmable outputs (PGMs).
Simple, direct and logical programming
Event Call Direction: The Spectra Series Control Panel events are divided into 5 groups of events. Each of these
event groups can be programmed with a separate dialing sequence.
Two 32-digit Central Station Telephone Numbers and one 32-digit Back-up Telephone Number
Contact ID, Pager Format and many more High-Speed Communication Formats
"False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable
Delay Before Alarm Transmission, and Recent Closing Report
Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Arming with
Keyswitch
256 Event Buffer with time stamp
Optional 5A Alarm Relay (1758 and 1758EX only)
Telephone Line Supervision
Keypad activated panic alarms
Compatible with Winload software for Windows®
And much, much, more…
1.2 SPECIFICATIONS
1.2.1 SPECTRA CONTROL PANEL
AC Power: 16VAC transformer with minimum 20VA rating (Rec.: 40VA), 50-60Hz
(UL tested to 60Hz only)
Battery: 12VDC, 4Ah
Aux. Power: 600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
Bell Output: 1A, fuseless shutdown @ 3A (1725/EX and 1728/EX) or 2.5A (1758/EX)
PGM1 Output: 150mA
PGM2 Output: 2.5A (1758/EX only)
1.2.2 SPC-319 L
IBERATOR
W
IRELESS
M
ODULE
Power input: 9-16VDC
Current Consumption:70mA
Frequency Hopping: @ 902MHz - 928MHz or 868MHz
Range of Detectors & Contact Switches: 1000m (3280’) or 300m (984’) for 868 MHz
Range of Remote Controls: 30m (100‘)
Data Rate:10 KB/s
Sensitivity:-105dBm
Dimensions (without antenna): 15cm H x 16cm L x 3cm W (6”H x 6.5”L x 1.1”W)
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Operating Humidity: 85%
PGM Outputs:1 + 1(optional)
PGM Output current: 5A relay
1.2.3 HAND-HELD REMOTE CONTROLS
Water Resistant
Range: 30m (100ft.)
Battery: Lithium 3V (CR2032)