EasyManua.ls Logo

Spectra 1725 - PGM Delay, Type, and Options

Spectra 1725
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
R
EFERENCE
& I
NSTALLATION
M
ANUAL
9.3 PGM DELAY
Section [066] = PGM1, [067] = PGM2, [068] = Global PGM: 000 = Follows De-activation Event, 001-255
seconds, Default = 5 seconds
Instead of de-activating the PGM on the occurrence of a specific event, the PGM will de-activate after the period
programmed here has elapsed.
If a PGM Delay is programmed, the de-activation event can be used as a second activation event.
9.4 PGM TYPE
Section [127] = PGM1, [129] = PGM2, [131] = Global PGM
These three options have been added to this new version of the Spectra control panels allowing you to specify the
PGMs as normally open (N.O.) or normally closed (N.C.). Any PGM in the Spectra system that has been
programmed to follow the Global PGM will also follow the Global PGM type defined by this option.
Section [127] - General Options
Option [8] OFF = PGM1 Normally Closed (Default)
Option [8] ON = PGM1 Normally Open
Section [129] - General Options
Option [8] OFF = PGM2 Normally Closed (Default)
Option [8] ON = PGM2 Normally Open
Section [131] - Arming/Disarming Options
Option [8] OFF = Global PGM Normally Closed (Default)
Option [8] ON = Global PGM Normally Open
9.5 PGM2 STROBE OPTIONS (1758 & 1758EX ONLY)
Section [129] - General Options
Option [1] OFF = PGM2 Output is Steady (Default)
Option [1] ON = PGM2 Output is Pulsed (Strobe)
With option [1] enabled, PGM2 will flash on and off whenever activated. Otherwise, it will provide a steady output.
Option [2] OFF = PGM2 Pulse When System Armed Disabled (Default)
Option [2] ON = PGM2 Pulse When System Armed Enabled
Whenever the system is armed, PGM2 will flash once every 30 seconds until the system is disarmed.
Option [3] OFF = PGM2 Pulse on Arm/Disarm Disabled (Default)
Option [3] ON = PGM2 Pulse on Arm/Disarm Enabled
With this option enabled, PGM2 will flash once to indicate the system has been armed and will flash twice to indicate
that the system has been disarmed.
9.6 ALARM RELAY OPTIONS (1758 & 1758EX ONLY)
Section [127] - General Options
Option [7] OFF = Alarm Relay Follows Bell Output (Default)
Option [7] ON = Alarm Relay Follows Global PGM
With this option off, the optional Alarm Relay will activate or de-activated whenever the Bell Output has activated or
de-activated. With the option on, the Alarm Relay will activate or de-activated whenever Global PGM has activated
or de-activated.

Table of Contents