PART 8: REPORTING AND DIALER SETTINGS
The following section explains all the features and options that must be programmed in order for your security system to
properly report system events to a central station. When an event (e.g. zone in alarm) occurs in the system, the control panel
verifies if a report code was programmed in the section corresponding to the event (except Ademco Contact ID All Codes”).
If a report code was programmed, the control panel will dial the central station telephone number defined by the Event Call
Direction feature. When the central station answers, the control panel will transmit the System Account Code, followed by the
programmed Report Code.
Pulse
DTMF
(Tone)
Program 1 or 2-digit (1-FF)
report codes into sections
[160] to [213] where each
section represents up to 4
events in the system.
The control panel
automatically generates
all report codes. You do
not have to program any
report codes.
Program the 2-digit report
codes corresponding to the
Contact I.D. Table into
sections [160] to [213] where
each section represents up to
four events in the system.
Program FF to use the default
Contact ID Report Code .
"All Codes"
Option
[3]
ON
- Section
[136]
"Programmable"
Option
[3]
OFF
- Section
[136]
Central Station Telephone Numbers 1 & 2
Sections [151] & [152]
Back-up Number
Section [153]
Partition Account
Numbers
Partition 2
Reporting Account Number 2
3 or 4 digits (0-F) in
Section [144]
Partition Account Number 1
3 or 4 digits (0-F) in
Section [143]
Partition 1
Reporting Formats
Section [140]
1
st
digit = CSTN#1
2
nd
digit = CSTN#2
Related Features
Delay Before Alarm Transmission
Section [080]
Pager Format Delay Transmission
Section [083]
Recent Closing Delay
Section [085]
Power Failure Report Delay
Section [086]
Auto Test Report
Sections [087] & [110]
Report Disarm Options
Option [1] - Section [131]
Report Zone Restore Options
Option [6] - Section [132]
Reporting/Dialer
Option [3] - Section [135]
Event Call Direction
Defines which Central Station Telephone Numbers each group of
events will report to.
Section
[137]
Option
[1]
ON
= Call Telephone #1 for Arm/Disarm Report Codes
Option
[2]
ON
= Call Telephone #2 for Arm/Disarm Report Codes
Option
[3]
ON
= Call Telephone #1 for Alarm/Restore Report Codes
Option
[4]
ON
= Call Telephone #2 for Alarm/Restore Report Codes
Option
[5]
ON
= Call Telephone #1 for Tamper/Restore Report Codes
Option
[6]
ON
= Call Telephone #2 for Tamper/Restore Report Codes
Section
[138]
Option
[1]
ON
= Call Telephone #1 for Trouble/Restore Report Codes
Option
[2]
ON
= Call Telephone #2 for Trouble/Restore Report Codes
Option
[3]
ON
= Call Telephone #1 for Special System Report Codes
Option
[4]
ON
= Call Telephone #2 for Special System Report Codes
Maximum Dialing Attempts
Section [081]
Delay Between Dialing
Attempts
Section [082]
Alternate Dial
Option [4] - Section [136]
[1]
= Ademco Slow
[3]
= Sescoa
[2]
= Silent Knight Fast
[4]
= Ademco Express
[5]
= Ademco Contact ID
[6]
= Pager
Figure 8-1: Event Reporting