4.4.1 PARTITION 1 ASSIGNMENT
Sections [302] to [348] = User Codes 002 - 048
Option [1] OFF = Deny access to partition 1
Option [1] ON = User code has access to partition 1 (default)
If Partitioned (see page 41), user codes with this option enabled can arm and disarm partition 1.
If the system is not partitioned, you must assign partition 1 to the User Access Code.
Otherwise, the User Access Code will be considered disabled.
4.4.2 P
ARTITION
2 A
SSIGNMENT
Sections [302] to [348] = User Codes 002 - 048
Option [2] OFF = Deny access to partition 2 (default)
Option [2] ON = User code has access to partition 2
If the system is partitioned (see page 41), user codes with this option enabled can arm and disarm partition
2. If the system is not partitioned, the control panel ignores this option.
4.4.3 B
YPASS
P
ROGRAMMING
Sections [302] to [348] = User Codes 002 - 048
Option [3] OFF = Bypass Programming Disabled
Option [3] ON = Bypass Programming Enabled (default)
User codes with this option enabled can perform Bypass Programming in assigned partitions.
4.4.4 STAY ARMING
Sections [302] to [348] = User Codes 002 - 048
Option [4] OFF = Stay Arming Disabled
Option [4] ON = Stay Arming Enabled for selected User Code (default)
User codes with this option enabled can Stay Arm assigned partitions.
4.4.5 FORCE ARMING
Sections [302] to [348] = User Codes 002 - 048
Option [5] OFF = Force Arming Disabled (default)
Option [5] ON = Force Arming Enabled for selected User Code
User codes with this option enabled can Force Arm assigned partitions.
4.4.6 ARM ONLY
Sections [302] to [348] = User Codes 002 - 048
Option [6] OFF = Arm Only Disabled (default)
Option [6] ON = Arm Only Enabled for selected User Code
The user code with this option enabled can arm assigned partitions but can not disarm any partitions. The type
of arming is dependent on the other User Code Options selected. Please note that with the Arm Only option,
the user can cancel a recently armed system by re-entering the access code before the end of the Exit Delay.
4.4.7 PGM A
CTIVATION
Sections [302] to [348] = User Codes 002 - 048
Option [7] OFF = Arm, Disarm & PGM activation for selected User Code (default)
Option [7] ON = PGM only for selected User Code
With option [7] off, entering the access code will arm or disarm the system as well as activate or deactivate
a PGM. The appropriate PGM Activation/Deactivation Event must also be programmed (see page 39).
With option [7] on, the control panel will ignore all other User Code Options. Therefore, entering the access
code will only activate or deactivate the PGM.