16
LCM Replacement Instructions
90970024
REPLACE THE LCM
Removing the LCM
1. Power off the library—Ensure that the library and flash card are both
idle, and then power the library off. Press and hold the front panel
power button for one second.The power-off sequence takes
approximately two minutes while the library allows applications to
shut down gracefully.
2. Disconnect any cables connected to the LCM and remove any USB
devices, if present.
3. Loosen the finger screws securing the LCM to the chassis by hand or
with a #2 Phillips screwdriver.
4. Grasp the finger screws and pull the LCM directly toward you to slide
it out of the chassis.
5. Set the LCM aside for return to Spectra Logic.
Figure 2 LCM replace–power off the library.
Figure 3 Remove the screws securing the LCM to the chassis.
Power button
Finger screws
(one each side)
Flash card
retaining plate