6
LCM Replacement Instructions
90970024
Gathering Tools and Supplies
A new Spectra T50e LCM module
A #2 Phillips screwdriver
Continuing Backups
If the LCM is malfunctioning, you have no control of the library through
the Library Controller (LC) on the front panel or through the Remote
Library Controller (RLC). A malfunctioning LCM can also affect robotics
and tape drives. Backups are interrupted if the robotics or tape drives are
affected and cannot be restarted until after the LCM is replaced.
Preparing for Replacement
You have a Valid Backup Library Configuration Whenever you modify the
configuration of the library or a partition, you have the option of saving the
configuration to a USB storage device, as described in the Spectra T50e
Library User Guide. The saved configuration can be used to restore a lost
configuration.
If you previously saved the library configuration on a USB storage device
or uploaded it to a file on your computer, locate the most current
configuration file before beginning the replacement procedure. You can
use this saved configuration to restore the library configuration after you
replace the LCM.
If you have a valid saved configuration, continue with Replace the LCM on
page 16.
You do
not
have a Valid Backup Library Configuration If do not have a valid
backup library configuration, or are unable to locate it, you may need to
reconfigure your library manually after replacing the LCM.
In this case, it is important to write down the following library information
before continuing. The items to write down are listed here and described
below:
Option keys
Encryption keys
Partition information
Network information
Email Users and SMTP IP Address
AutoSupport Log Profile information for each profile
Caution
Do not attempt to save the library configuration if the LCM is malfunctioning. Any
information saved at this point may be corrupted.