8
5 Technical specifications
FEATURES K1200 K1700 K2300 Units
Weight
185
202 219 Kg
Height
1110
1150 1210 mm
Width
615
600 665 mm
Depth
675
655 730 mm
Diameter of the flue pipe
80
100 100 mm
Reservoir capacity
30
30 45 Kg
Maximum heating
capacity
284
384 520
Maximum Heat Output to
boiler
10.3
14.2 18.8 kW
Maximum Heat Output to
room
2.2
3 3.3 kW
Minimum Heat output to
boiler
4.1
4.3 4.3 kW
Minimum Heat output to
room
1.2
0.8 0.8 kW
Minimum fuel
consumption
1.1
1.1 1.1 Kg/h
Maximum fuel
consumption
2.76
3.9 5.1 Kg/h
Rated electrical current
100
134 134 W
Electric power at start-up
(<10 min.)
406
434 434 W
Rated voltage
230
230 230 V
Nominal frequency
50
50 50 Hz
Efficiency @ nominal
input.
94.3
91.1 89.2 %
Efficiency @ reduced
input.
96.35
93.8 93.8 %
Combustion gas flow
(max.)
10.2
14.8 18.8 g/s
Combustion gas flow
(min.)
4.7
6.9 6.9 g/s
Max. flue gas temperature
93
128 153 ºC
Min. flue gas temperature
64
66 66 ºC
CO emissions at rated
thermal power
0.016
0.02 0.02 %
CO emissions at reduced
thermal power
0.027
0.024 0.024 %
Flue draught
12
12 12 Pa
Stove water volume 19 22 22 W
Sound level max. 49.1 49.1 49.1 dB(A)