MC521 PRO Control Box
52 Document # 204090 REV D • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2017, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
03.23.2017
Values shown as grayed out do not aect moon of the door and may need to be adjusted to suit the applicaon
Attachment 10
Table 6 Recommended Values for Dual Egress Swing Doors with Motor 2 as In-Swing
Index Description Heavy Weight Doors (350lbs)
Low Energy Full Energy
20 Open speed, revoluons per second 07 25
21 Check speed, revoluons per second 06 05
22 Stall speed, percent of PWM counts See Aachment 11
23 Open check 20 45
24 Magic Touch sensivity 00 00
25 Magic Touch hold open me HH=55
KP=22
HH=40
KP=16
26 Hold-open delay HH=55
KP=22
HH=15
KP=06
27 Open torque, percent of full torque 23 75
28 Check torque, percent of full torque 25 75
29 Stall torque, percent of full torque 25 25
30 Open Check Boost* 09 14
33 Obstrucon me HH=50
KP=20
HH=50
KP=20
34 Open Acceleraon Slope 60 60
35 Open Braking Slope 20 35
36 Delay before door moon. Motor 2. 00 00
HH = Hand Held
KP = Key Pad