MC521 PRO Control Box
10 Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS
Copyright 2015, Stanley Security Solutions. All rights reserved. Reproduction in whole
or in part without the express written permission of Stanley is prohibited.
10.21.2015
Table 3. Settings
Index Min.
Value
Max
Value
Description Defaults
Single Dual
00 05 35 Open speed, increment by 1. 25 25
01 05 18 Close speed, revoluons per second. 12 12
02 03 10 Check speed, revoluons per second. 04 04
03 10 99 Open check length. 35 35
04 10 99 Close check length. 30 30
05 00 99 Reduced open posion, percent of full opening (00=full open, 99=full close). 01 01
06 01 99 Hold open delay (0 to 25 sec.). 06 06
07 00 03 Lock Logic, 00 = Fail Safe, 01 = Fail Secure, 02 = Dura-Max Fail Safe,
03 = Dura-Max Fail Secure.
NOTE: For locks with circuit board, set to 01 Fail Secure. For locks
with no circuit board, set to Fail Safe or Fail Secure.
01 01
08 05 75 Open torque, percent of full scale. 25 40
09 00 75 Close torque, percent of full scale. 25 15
10 00 75 Check torque, percent of full scale. 25 10
11 00 01 Dura-Glide funcon switch type: 00=double pole rotary, 01=rocker. 01 01
12 00 01 2S Operaon, 0=o, 1=on. 00 00
13 01 60 Obstrucon Time Delay (.01 – 1.5 sec). 20 40
14 20 60 Open Acceleraon, (larger value=faster acceleraon). 60 60
15 20 60 Open Braking, (larger value=increased braking).
20=No open braking.
54 54
16 20 60 Close Acceleraon, (larger value=faster acceleraon). 20 20
17 20 60 Close Braking, (larger value=increased braking).
20=No close braking.
40 40
18 00 02 00 = O (Delay Egress), 01 = 15 sec. delay, 02 = 30 sec. delay. 00 00
19* 00 04 Safety Logic, Do Not Change.
Must be set to 04.
04 04
20 00 01 Hold Beam Type.
00 = Optex, 01 = Photo Beam Pro.
01 01
21* 01 50 Lock Delay (0.1 – 5.0 sec). 01 01
22 00 64 Open Stop.
Distance (1/8” increments) from full open the door will stop.
06 06
24 00 01 Access Control Pro.
00 = o, 01 = on.
00 00
25 00 03 Press Time, 00 = least amount, 03 = most amount of pressing.
Aer obstrucon meout, the number of seconds the door presses
at Full Closed.
02 02
28 00 20 Open Check Boost. Transion speed from braking to check. 02 02
29 00 20 Close Check Boost. Transion speed from braking to check. 02 02
NOTE: Door must be cycled open for changes to be stored in permanent memory.