Special Application Tools
defines +60°C as the limit for thermal rise over ambient of a contactable surface (e.g. if the ambient is 2C, the
surface limit is 85°C.) Since the default limit is 85°C inside the tool regardless of ambient, no external surface can
exceed this value no matter what the ambient temperature.
STANLEY allows the temperature limit adjustment to provide flexibility to the professional user. Once a customer
changes the setting from the factory default, it is their responsibility to ensure the safety of the user.
Controller parameter settings can have a significant effect on tool operating temperatures.
5.2.10 Setting Torque, Angle, and Other Operating Parameter
WARNING
EXCESSIVE TORQUE CONDITION
To Avoid Injury:
Only trained and qualified personnel should program controllers.
Never set control limits above the maximum rating of the tool.
Setting control limits above the maximum rating of the tool can cause high reaction torque.
Always test for proper tool operation after programming via the controller.
CAUTION
Ensure fastener and/or system will withstand the level of torque generated by the tool. Excessive torque may
cause breakage and possible personal injury.
The Alpha controller can be setup to change tightening Jobs or Tasks from the tool’s MFB.
5.2.11 Assembly (Forward) Operation
Prepare to resist the tool’s torque reaction.
Keep the tool pointed straight at (perpendicular to) the fastener. Start the tool by depressing the start trigger
switch. The tool stops after reaching torque.
Release start trigger switch after the cycle is complete.
5.2.12 Disassembly (Reverse) Operation
Prepare to resist the tool’s torque reaction which will be the opposite of the assembly reaction.
Start the tool by depressing the start lever or trigger. The tool is not running inside of a strategy so it will not
stop on its own.
Release start lever after sufficient time or rotation to stop the tool.
5.3 Special Application Tools
5.3.1 Exposed Gear Socket Tools

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley QB Expert and is the answer not in the manual?

Stanley QB Expert Specifications

General IconGeneral
BrandStanley
ModelQB Expert
CategoryController
LanguageEnglish

Related product manuals