Maintenance
Fault Possible Cause Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Tool does not run
Tool cable Replace
Physical inspection:
worn, frayed, or
broken connections
or wires
Replace tool cable
Tool Replace/Repair
Swap with known,
good operating tool
Replace/Repair tool
Calibration Factors Verify/Adjust Zero or Span Fault
Verify and or adjust
tool calibration
factor(s) to
match calibration
factor(s) for tool.
May require tool
recertification.
Strategy Verify/Adjust
No bolt count on
the Run screen for
the selected Job/
Task
Create new
strategy
Cycle Abort set to
zero (0)
Set higher amount
on Cycle Abort
Torque Target
set to zero (0) on
torque control
strategy
Set higher amount
on Torque Target
Angle Target set
to zero (0) on angle
control strategy
Set higher amount
on Angle Target
Tool Speed set to
zero (0)
Set higher amount
on Tool Speed
Power set to zero
(0)
Set higher amount
on Power
Acceleration set
to zero (0)
Set higher amount
on Acceleration
Fault Various errors
Fault displayed on
screen
See Fault Guide
(Section 9.2.1
Fault Guide” on
page 181)
STOP condition or
input
Remove STOP
condition
Press and hold
trigger and view
message on display
See Message Guide
(Section “9.3
Message Guide” on
page 189)