Maintenance
Fault Possible Cause Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Position Feedback
Fault!
Defective tool
Replace defective
tool
Exchanging known
good tool can
verify the tool is the
cause of failure
Replace defective
tool
Re-engage and lock
pins in connector in
handle
Visual/mechanical
inspection of pins
in tool handle
connector
Re-engage and lock
pins in connector in
handle
Tool cable longer
than 60 meters
Reduce total cable
length to < 60
meters
Whip was removed
from extension
cable and
connected directly
to the controller,
which then cleared
the error
Fault condition
resets when cable
length is reduced.
Transducer Span
Fault!
Torque Cal. set
to a non-standard
value (i.e. greater
than 20% variance
from Nominal
Cal.)
Set Torque Cal. to
the specific torque
calibration value for
the tool
Read the Nominal
Torque Cal. value
from the tool and
compare it to the
specific Torque
Cal.
May require tool
recertification
Wrong tool
parameters in tool
memory board
Download correct
tool INI file to tool
Wrong values
indicated under
SERVICE>TOOL
screen
Download correct
tool INI file to tool
Defective tool
Re-engage and lock
pins in connector in
handle
Visual/mechanical
inspection of pins
in tool handle
connector
Re-engage and lock
pins in connector in
handle