185
Maintenance
Fault Possible Cause Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Temperature Fault!
Wrong value
in Temperature
parameter
Modify
Temperature
parameter value
Viewed
Temperature value
under SETUP->
OTHER-> TOOL tab
and compared with
Temperature value
on ANALYZE screen
Modify
Temperature
parameter value.
The maximum for
handheld tools
is 85˚C. The
maximum for
xtured tools is
125˚C.
Excessive duty cycle
Use a larger tool for
the job
Tool is hot to touch
and shuts down:
QPM tools
shutdown when
tool internal
temperature
reaches and stays
above programmed
set point for 8
minutes
This error
automatically resets
when temperature
drops and stays
below trip point for
8 minutes on QPM
tools.
It can also be reset
by cycling power,
however, if the
tool has not cooled
down this error
will reappear in 8
minutes.
For fixtured tools
turn off Soft Stop.
Inefficient
Rundown Strategy
Contact STANLEY
Assembly
Technologies for
help on modifying
strategy
Tool is hot to touch
and shuts down:
QPM tools
shutdown when
tool internal
temperature
reaches and stays
above programmed
set point for 8
minutes
To prevent an
over temperature,
modify the
strategy by raising
downshift speed
or eliminating the
downshift; Also
try a multi-step
strategy with a
Delay Between
Steps of at least
0.5 seconds.
For fixtured tools
turn off Soft Stop.