Maintenance
Fault Possible Cause Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Tool
Communications!
Defective tool,
cable, or controller
Replace defective
tool, cable, or
controller
Exchanging
known good
tools controllers
and cables can
determine which
caused a failure
Replace defective
tool, cable, or
controller.
If the controller
is found to be
defective, return to
STANLEY Assembly
Technologies for
repair.
If the tool is found
to be defective,
see the next row
for troubleshooting
and repair.
Tool Memory Board
failure
Replace the Tool
Memory Board
Tool found to be
defective
Replace and
reprogram the Tool
Memory Board in
the handle of the
tool
Defective tool
Re-engage and lock
pins in connector in
handle
Visual/mechanical
inspection of pins
in tool handle
connector
Re-engage and lock
pins in connector in
handle
Tool not electrically
connected to
controller
Check tool whip/
extension cable
connections and
ensure they are
tight
No values
indicated under
SERVICE>TOOL
screen
Connect tool to
controller