SERVICE Area
QB Expert Alpha Controller
76
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the Run screen. See
section “3.1.2.6 Exit” on page 52.
3.2.1.2 Counters Tab
Each of the three counters increments at the same time after an OK Fastening cycle.
Odometer – Cannot be reset. Indicates the total number of OK Fastening cycles the attached tool has performed
over its lifetime.
PM Counter – Causes the preventive maintenance indicator to illuminate (on front panel and tool) when this value
exceeds the PM Threshold.
Trip Counter – Counts the number of OK fastening cycles between resets.
Use the RESET interactive menu button to reset (back to zero) either the PM Counter or the Trip Counter.
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the Run screen. See
section “3.1.2.6 Exit” on page 52.
3.2.1.3 CAL Tab
This area is used to set the calibration value(s) for the attached tool.