Energy yield data Storage resolution/period
10-minute values 31 days
Daily values 13 months
Monthly values 30 years
Annual values 30 years
Total yield permanent
3.6.2 Network (TCP/IP)
The device can transfer yield data and event messages via the TCP/IP
interface to the Internet portal
http://www.solare-energiewende.de
server
. The yield data can be displayed graphically in the Internet
portal as illustrated below. This service is free of charge for a period
of 2 years from the time of registration. The following applies:
n Before the Internet portal can be used, the user must go to
www.steca.com/portal to register
.
n The local network settings must be set at the inverter in order to
establish a connection to the Internet portal server. This can be
performed automatically or manually:
Automatically: If IP addresses are automatically assigned in
your network (DHCP), then no settings need to be made at the
inverter.
Manually: If IP addresses are not automatically assigned in your
network, then you must manually set the inverter network set-
tings via Settings Network; see
Ä
TCP/IP network“ on page 17
n The address of the Internet portal server is permanently stored
in the inverter and cannot be changed.
n Once the network connection is established, the inverter auto-
matically starts non-encrypted transmission of data to the
server.
Notice
The network cable must be disconnected in
order to prevent transmission of the data, or
data transmission must be disabled according to
Ä
TCP/IP network“ on page 17.
EN
750.661 | Z03 | 2016-09-12
21