EasyManua.ls Logo

Steca coolcept3 - Technical data; Inverter

Steca coolcept3
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Technical data
8.1
Inverter
8.1.1 StecaGrid 3203/3203x/4003/4003x
StecaGrid 3203/x StecaGrid 4003/x
DC input side (PV generator connection)
Number of DC inputs 1
Maximum start voltage 1000 V
Maximum input voltage 1000 V
Minimum input voltage for
feeding-in
250 V
Start input voltage 250 V
Rated input voltage 415 V 515 V
Minimum input voltage for rated
output
300 V 375 V
Number of MPP trackers 1
Operating input voltage range 250 ... 800 V
Maximum input current 11 A
Maximum short-circuit current +20 A/– 13 A
Rated input current 8 A
Max. current refeed to PV gener-
ator
0 A
Maximum input capacity at max-
imum output effective power
3,300 W 4,100 W
Nominal input power
(cos φ = 1)
3,300 W 4,100 W
Derating / power limiting occurs automatically when:
n input power > max. recommended PV power
n Cooling is inadequate
n Input current too high
n Output current too high
n Grid frequency too high (in accordance with country set-
ting)
n Limiting signal on external interface
n Output power limited (set on the inverter)
DC side (storage connection)
1)
Voltage 580 V ... 1000 V
Maximum current 10 A
EN
750.661 | Z03 | 2016-09-12
57

Related product manuals