61FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
Check leads between control unit 
and diagnostic jack
– Connect the test lead, b 7.3.2
: Measure the resistance between 
red lead (1) and black plug (2) of 
the diagnostic cable
Target value: < 10 ohms.
: Measure the resistance between 
black lead (1) and red plug (2) of 
the diagnostic cable
Target value: < 10 ohms.
If the target values are not 
attained
– Check that screw on control unit 
(ignition module) and screw on 
angled terminal socket are firmly 
seated, if necessary, remove 
screws and clean with angled 
terminal socket, then reinsert and 
tighten
5904RA286 TG
1 2
5904RA547 TG
1 2
– Check continuity between blade 
receptacle and angled terminal 
socket 
– Blade receptacle and angled 
terminal socket must be firmly 
connected with one another; in 
the event of contact problems, 
the M-Tronic wiring harness must 
be replaced, b 7.4.
Check leads between solenoid 
valve and diagnostic jack
– Connect the test lead, b 7.3.2
: Disconnect the plug (1) from the 
solenoid valve (2)
: Measure the resistance between 
red lead (1) at the plug of the 
solenoid and black plug (2) of the 
diagnostic cable
 
Target value: < 10 ohms
2
5904RA282 TG
1
5904RA288 TG
1
2
: Measure the resistance between 
black lead (1) at the plug of the 
solenoid and red plug (2) of the 
diagnostic cable
Target value: < 10 ohms
If the target values are not 
attained
– Check contact surfaces between 
lug and screw and check leads 
for interruptions, e. g., cable 
breakage – the leads must be 
firmly seated in the blade 
receptacle and in the lug.
5904RA289 TG
1
2