60 FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
7.3.5 Checking the start 
detection function
– Carry out test preparations, 
b 7.3.1
– Check contacts and operation, 
b 7.3.3
– Connect the test lead, b 7.3.2
: Disconnect the plug (1) from the 
solenoid valve (2)
: Remove screws (1)
: Pull out the blue lead (2) and red 
lead (3)
– Move choke lever to 
position "}" – slide control or 
lever for stop function on control 
handle is not pressed
2
5904RA282 TG
1
1
5904RA283 TG
1
3
2
– Connect M-Tronic test lead to 
multimeter
: Insert black plug (1) in the "com" 
/ "ground" jack and the red 
plug (2) in the "volt" / "ohm" jack
– Set multimeter to "diode test"
: Test diode on switchgear (3) 
(microswitch) in accordance with 
multimeter instruction manual
If the switchgear (microswitch) is 
intact and the choke lever is set to 
the "}" position, the following 
target values will be attained:
– Measurement in direction of flow, 
target value: 0.3 volts to 0.7 volts
– Move choke lever to position "F" 
– slide control or lever for stop 
function on control handle is not 
pressed
– Reverse-biased measurement
Target value: 1.2 volts to infinity
– If target values are not attained, 
replace M-Tronic wiring harness, 
b 7.4
1
5904RA284 TG
2
3
7.3.6 Checking the wiring 
harness
– Carry out test preparations, 
b 7.3.1
– Check contacts and operation, 
b 7.3.3
– Move choke lever to position "F"
Checking the ground connection
: Measure the resistance between 
blade receptacle (1) and 
screw (2) at the control unit 
(ignition module)
Target value: < 10 ohms.
If the target values are not 
attained
– Check electrical leads for 
interruption, e. g., cable 
breakage – if necessary, replace 
M-Tronic wiring harness, b 7.4.
5904RA287 TG
1
2