0478-131-3050-A
33
English 
10 Installing the Robotic Mower
► Press the OK button on the control panel to approve or 
change the active times. Before modifying active times, 
see @ 14.5.
The active times for Monday are displayed and the menu 
item "Confirm active times" is highlighted.
► Confirm all active times by pressing the OK button on the 
control panel. The display will show the next day's mowing 
plan for you to approve or modify.
In the case of small mowing areas, mowing may not be 
necessary every day. In this case, no active times will be 
displayed, and the menu item "Delete all active times" is 
not available. Days without active times must also be 
confirmed by pressing the OK button on the control panel.
Next to each menu item, one of the following symbols is 
displayed:
To complete programming:
► Confirm the active times for Sunday.
The final mowing plan will be displayed.
► Confirm the mowing plan by pressing the OK button on the 
control panel.
The final step of the installation assistant will be called up.
► Select "Change" if you need to modify one of the active 
times.
Before changing the active times or mowing duration on your 
iMow, see the chapters on the Mowing Plan, @ 14.5, 
@ 14.6 and @ 14.7. 
NOTICE
If you have a sprinkler system, program the robotic mower 
to avoid active watering times to reduce the likelihood of 
damage to the sprinkler heads from contact with the mowing 
blade. The mower and sprinkler system should never be run 
at the same time.
NOTICE
Avoid contacting the perimeter wire when de-thatching or 
aerating the lawn. Also use caution when operating a line 
trimmer near the perimeter wire. De-thatching, aerating and 
trimming operations can result in a cut or damaged 
perimeter wire. Refer to your sketch of the mowing area and 
take special care to avoid the perimeter wire when 
performing these operations.
The displayed active times can be changed. Select 
the time interval to be changed using the navigation 
pad and open it by pressing the OK button on the 
control panel, @ 14.6.
Additional active times can be programmed. Select 
the menu item "New active time" and open it by 
pressing the OK button on the control panel.
Select up to three active times per day with their start 
and end times in the selection window. Confirm it by 
pressing the OK button on the control pane.
Active times can be deleted. Select the menu item 
"Delete all active times" and confirm it by pressing the 
OK button on the control panel.