0478-131-3050-A
90
English
26 Installation Examples
Mowing area around a free-standing house with external
docking station (1):
Docking station: Location next to the garage (B) and
behind the house (A).
Wire clearances:
Clearance from obstacles which can be travelled on,
such as patios and paths with a maximum height
difference between lawn area and obstacle of +/- 0.4 in.
(1 cm): 0 in. (0 cm)
Clearance from high obstacles: 11 in. (28 cm)
Search loops: Installation of two search loops (2) with a
minimum distance from the corridor entrance of 6.6 ft.
(2 m) for using the drive home function. Note the minimum
clearance from corners, @ 11.9.
Programming: Set the size of the mowing area and at least
one starting point (2), @ 15.6.
Points to note: Installation of a corridor (4) with funnel-
shaped entrance area (3) with a wire clearance of 9 in.
(22 cm). The corridor leads to the external docking
station (1). Increase the wire clearance (5) in the corridor
to the width of the base plate with a length of (3.3 ft. (1 m))
in front of the docking station. Note the space requirement
in the corridor and beside the docking station.