EasyManua.ls Logo

Still RX70-16 - Checking the fork arms

Still RX70-16
380 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Maintenance
Remaining ready for operation
Servicing the battery
NOTE
Battery maintenance is carried out in accor-
dance with the battery manufacturer's opera-
ting manual!
WARNING
There is a risk of damage, short circuit
and explosion.
Do not place any metal objects or tools
on the battery. Keep away from naked
flames and fire. Smoking is forbidden.
Checking the battery charge status
Remove the bottom plate; see Chap-
ter "Installing and removing the bottom
plate", P. 5-318
Mind the accelerato
rasyoudoso.
7312_003-040
1
With maintenance-free batteries, check the
charge status at the inspection window (1):
Green: The batter
y is optimally charged.
Black: The battery charge status is no
longer optimal. The battery should be
recharged. After recharging, the indicator
changes back to green.
Transparent-(light-coloured): The charge
status is no longer adequate for reliable
starting. It is necessary to change the
battery.
Charging the battery
With batteries that are
not maintenance-
free, check the level of
the battery acid.
WARNING
The electrolyte (dilute sulphuric acid)
is poisonous and caustic.
Follow the safety regulations for
working with battery acid; see
Chapter "Battery acid", P. 2-47.
Check battery acid level.
334
174749 EN - 03/2017

Table of Contents