2 Safety
Safety inspections
NOTE
Please observe the definition of the following
responsible persons: "operating company"
and "competent person".
NOTE
Observe the TRGS 554 regulations and
national regulations of the country in which
the truck is being used.
Insulation testing
The truck insulation must have sufficient insu-
lation resistance. For this reason, insulation
testing in accordance with DIN EN 1175 and
DIN 43539, VDE 0117 and VDE 0510 must be
conducted at least once every year.
NOTE
Contact your service centre to arrange for an
insulation test.
Measuring the insulation resistance of
the electrical system
NOTE
Nominal battery voltage < test voltage < 500 V.
Ensure that all voltage sources have been
disconnected from the circuit to be tested.
Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 1000
/V for
nominal battery voltage against ground.
Contact the authorised service centre.