Objet500 User Guide 6 Operating and Maintaining the Objet500 3DPrinter
DOC-07027 Rev.E 6-82
Test Name Description Possible Reason for Failure
Head/BlockHeaters Teststheheatersintheprintheads
andintheprint-blockbody.
Faultyheatersorthermistors.
UVLamps TestseachUVlampattheHigh
Qualitypowerlevel.
FaultyUVlamp.
FaultyUVpowersupply.
DisconnectedUVcable.
AxesLimit Teststhehardwareandsoftware
limitsofallaxes.
Faultyhardwaresensors.
WrongMax Positionparameter.
ParameterSanity
Check
Comparesthevaluesofallprinter
parameters(incfgfiles)tothe
requiredvalues.
Oneormoreoftheprinterparameters
isnotwithintherequiredrange.
DetailsappearintheBITreport.
Vacuum Teststhevacuumlevelintheprint
block.
Faultyvacuumsensor.
Vacuumleakage.
Wrongparameters.