SPECIFICATIONS
14
3.1 TABLE OF SPECIFICATIONS (continued)
MOTOR: (60 Cycle Compressors)
24KT MODELS ST ANDARD MODELS
Size: 40,50,60, 75HP 40,50,60, 75 & 100 HP
Type: C---Flanged, Open Dripproof, 460V, A.C., C---Flanged, Open Dripproof, 460V, A.C.,
Three Phase, 60 Cycles Three Phase, 60 Cycles
40
_
C Maximum Ambient Temperature 40
_
C Maximum Ambient Temperature
Options Available: 200V, 230V and 575V Options Available: 200V, 230V and 575V
T.E.F. C. Also Available T.E.F.C. Also Available
Starter: 460V Full Voltage Magnetic 460V Full Voltage Magnetic
Options Available: 200V, 230V and 575V Options Available 200V, 230V and 575V
Speed: 1770 RPM 1770RPM and 3550RPM (100HP)
3.2 LUBRICATION GUIDE---STANDARD COM-
PRESSORS (All 12 Series; 16 Series --- 60 and
75HP)
Sullair standard compressors are filled with SRF
1/4000 fluid factory fill.
WARNING
!
Mixing of other lubricants within the compressor
unit will void all warranties!
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
highparticle level, corrosivegases orstrong oxidiz-
ing gases are present in the air.
F or extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance ofall other components is still recom-
mended as indicated in the Operator’s Manual.
3.3 LUBRICATION GUIDE --- STANDARD COM-
PRESSORS (16 Series --- 100HP)
Sullair standard compressor are filled with Sullube
32 fluid as factory fill.
WARNING
!
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullube 32 fluid should be changed every 8000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
highparticulate level, corrosivegasesorstrongoxi-
dizing gases are present in the air.
WARNING
!
“The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping.” (
I
)
Sullube 32should not beused withPVC piping sys-
tems. Itmayaffect thebond atcemented joints. Cer-
tain other plastic materials may also be affected.
(
I
) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance ofall other components is still recom-
mended as indicated in the Operator’s Manual.
3.4 LUBRICATION GUIDE---24KT COMPRES-
SORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid is required, use only Sullair 24KT
fluid.
WARNING
!
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullair recommends that a 24KT sample be taken
at the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self---addressed container is to be
supplied by your Sullair Representative at start---
up.Theuser will receivean analysis report withrec-
ommendations.
APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This
could result in a fluid change interval differing from
that stated inthe manual. Contact your Sullair deal-
er for details.