Installation, Operating and Maintenance Instructions (Original Instructions) 17
VMS Vertical Multistage Pumps
17
6 Transport
6.1 Transport
1. Transport the pump in the position as indicated on the pallet or packaging.
2. Make sure the pump is stable.
3. If present, observe the instructions on the packaging.
ATTENTION! If necessary, lift the pump using a hoist and suitable slings. Attach the slings to the
transport lugs on the packaging, where present.
ATTENTION! The pump must be lifted according to the current hoist guidelines. Only qualied
personnel are allowed to lift the pump.
ATTENTION! Do not lift the pump by using the frequency converter (if placed), electrical parts or
the motor cover. Be sure that the pump is always in balance.
ATTENTION! Pumps could tilt while lifting. Do not remove the lifting devices from the pump before
the pump is placed and mounted correctly.
X
1564-00
Figure 7. Transport positions
6.2 Storage
Fill the pump with glycol in order to protect it against the risk of frost.
Table 10. Storage
Storage
t
ambient
[°C] -10/+40
Max. rel. humidity 80% at 20 °C not condensing
6.2.1 Inspection during storage
Turn the shaft every three months and just before putting into operation.