Installation, Operating and Maintenance Instructions (Original Instructions) 5
VMS Vertical Multistage Pumps
5
2 Identication,service,andtechnicalsupport
2.1 Obtaining data and information from VMS and VMS H6 pumps
The nameplate indicates the type series / size, main operating data, and identication number. Please quote
this information in all queries, repeat orders, and particularly when ordering spare parts. If you need any
additional information or instructions exceeding the scope of this manual or in case of damage, please contact
Sulzer Customer Service.
40/10-2
0414352098
SN 01/2017 1234567-123
Made in NL
PO 600149091
Q/H
n.fix
Eff.
Seal
P/T
Conn.
40.8 m
3
/h / 195 m
2960rpm
75.1% (MEI>=0.70)
Code 14 E
PN25 -20/+120
o
C
PN16/25 NW80
ID
37kW(30.5kW)50Hz
V
Sulzer Pump Solutions Ireland Ltd.
www.sulzer.com
Clonard Road,
Wexford, Ireland.
29
VMS CF
1558-00
40/10-2
0414352098
SN 01/2017 1234567-123
Made in
NL
PO 600149091
Q/H
n.fix
Eff.
Seal
P/T
Conn.
40.8 m
3
/h / 195 m
2960rpm
75.1% (MEI>=0.70)
Code 14 E
PN25 -20/+120
o
C
PN16/25 NW80
ID
E
Frame 200(30.5kW)50Hz
Sulzer Pump Solutions Ireland Ltd.
www.sulzer.com
Clonard Road,
Wexford, Ireland.
29
VMS CF
1559-00
Figure 1. Pump with motor
Figure 2. Pump without factory mounted motor
H
1560-00
Figure 3. Duty point
Table 1. Nameplate description
Indication Meaning
VMS CF 40/10-2 Model key
37 kW (30.5 kW) Installed motor power (required power @ max. curve)
1 2
Frame 200 Motor frame size
50 Hz Nominal frequency
Q
3
40 m
3
/h Optimum capacity running at xed speed (see Fig. 3, ”Duty point”)
H 195 m Optimum head running at xed speed (see Fig. 3, ”Duty point”)
n x. 2960 rpm Rotation speed indication at which Q/H are given
E󰀨. 75.1% (MEI>=0.70) E󰀩ciency (Minimum E󰀩ciency Index)
Seal. Code 23 E Mechanical seal surface code (see Table 7, ”Seal code”)
E Easy access Seal construction type:
F = Fixed
E = Easy access
C = Cartridge
P/T PN 25 -20/+120 °C Maximum pressure at mentioned temperature range
4
Conn. PN16/25 NW80 Pressure class connection and connection size
ID 290414352098V Pump ID
SN WW / YYYY 1234567-123 Production week/year and production serial number > as built le
PO XXXXXXXXX Purchase order number
1. For pumps without a factory mounted motor: frame size.
2. When the installed motor power is less than the required power the pump is limited in its operating range. Consult your sales representative for details.
3. Optimum capacity of the hydraulics, restricted operating range (note 2.) not taken into account.
4. At lower pressure, a higher temperature is allowed (please consult your supplier).