Cyclo® BBB4
Operation & Maintenance Manual 9
Cyclo® BBB4
Installation onto Driven Shaft, continued
Taper-Grip® Bushing
Clean Driven
Shaft
2
Loosen socket head cap screws.
3
Remove (unscrew) Taper-Grip® bushing from the unit.
4
Clean all grease, oil and/or anti-seize paste from the driven shaft. Failure to do so
could result in damage to shaft.
Slide Taper-Grip® bushing onto driven shaft.
5
Inspect and test Taper-Grip® bushing on shaft.
•Checkshaftforburrs, corrosion, or warpage. Repair or replace shaft
as necessary.
•Slidebushingbackandforthalongshaft,checkingforsurfaceirregularities
and fit.
•Verifybushingissizedcorrectlyfortheshaftdiameter.