- 03 -
Why Test Locally
The reason you should NOT extend the power cable during the bench test
is because DC power drops quickly along the transmission. A bench test
helps you rule out all problems caused by power supply. Underpower cau-
-ses problems such as 1) ickering screen 2) unstable infrared (camera
reboots repeatedly) and 3) spinning dome.
When powered up, the speed dome automatically begins a self-diagnostic
process during which the camera will pan horizontally and vertically to
make sure PTZ, lens and other parts of the camera are functional. Please
contact our technical staff if a self-test does not happen on your unit. Ple-
-ase refrain from disassembling the unit before contacting us. Thanks for
your cooperation.
Questions? Ask support@sunba.net
Built-in self-test
Connection Good
Power Good
Video and Control Good
Tested Day and Night
Guess we are ready to mount it outside.
Phase 2: Mounting Outdoor
Good, the camera is working correctly. Now I just need to pick the right
extension cable and mount it outside!
≥30W
100V~250V
Data out
Data in
Router
POE+out
POE+
802.3at
100~250ft
POE+
ELV (Extra-LowVoltageSystem)
Wiring method:
Injector/Swith