14 SUNFAR E300 SERIES
4.3 State Monitor Parameter List
Monitor code Content Unit
d-0 Inverter current output freq Hz
d-1
Inverter current output current(virtual value)
A
d-2
Inverter current output volt(virtual value)
V
d-3 Motor rotate speed rpm
d-4 Inverter inner DC volt V
d-5
Inverter input AC volt(virtual value)
V
d-6 Set freq Hz
d-7 Analog input AI V
d-8 Running linear speed
d-9 Set linear speed
d-10 Input terminal state
d-11 Module temperature ºC
d-12 Analog output AO V
d-13 Reserved
d-14 1st failure record
d-15 2nd failure record
d-16 3rd failure record
d-17 4th failure record
d-18 Output freq of last failure Hz
d-19 Output current of last failure A
d-20 Output volt of last failure V
d-21 DC volt of last failure V
4.4 Inverter Simple Operation
4.4.1 Inverter initialization set
(1)Freq input channel selection([F0.0])
Inverter initialization set is different based on each model. Set this parameter as 0, inverter
freq is set by panel number.
(2)Operation input channel selection([F0.2])
Inverter initialization set is different based on each model. Set this parameter as [F0.2] =###0,
inverter stop and startup is controlled by the key of operation panel
STOP
RUN
E300 Series Mini-type Integrated Universal Inverter Manual