61
G. Adjust the height of the cam lever for the upper thread holder
Let the air out.
Set the distance between the lower part of the cam lever for the upper thread holder guide and the upper part of
the thread holder lever at 0.5mm by loosening the adjusting screw.
[ Fig. 35 ]
0.5mm