Page | 60
Appendix C
The Sunsynk Three-Phase Hybrid Inverter inverter is compatible with the SolarMan app,
via a Wifi or GSM data logger (See SolarMan instruction manual).
Appendix D
If an external Residual Current Device (RCD) is used it should be of Type A/AC with a
tripping current of 30mA or higher.
Use of RCDs
Residual Current Devices (RCDs): An RCD dedicated for an Inverter Energy System (IES)
may be used to meet the mechanical cable protection requirements of AS/NZS3000 for
the cable from the switchboard to the IES. If an RCD is installed the engineer must:
1. Disconnect all live conductors (including both active and neutral conductors) and
2. Be of the type specified in the inverter manufacturer’s instructions or as labelled on the
inverter.
We recommend the use of an RCD on all circuits and sub-circuits connected to the
Sunsynk Inverter. Below is the specifications for a Residual Current Breaker with
Overcurrent Protection (RCBO)
Earth-leakage protection class Type A
Earth-leakage sensitivity 30mA
Curve code C
Network type AC
Poles description 2P
Earth-leakage protection time delay Instantaneous
Appendix E
The Sunsynk inverter can be connected to the internet, but you need to add a data logger
to do this.
The inverter is compatible with Solar Man data-loggers, which you can obtain from us with
your distributor
1) LAN-Type Data Logger
2) Wi-Fi-Type Data Logger
3) GSM-Type Data Logger