60
Vent water and sediment of the segregator…
everyday
Vent water and sediment of the segregator…everyday. Shut off engine in a correct manner. Open
the vent valve on the bottom of the segregator. Screw the valve anticlockwise for circles, until
the valve goes down for 25mm. Vent the water in the catch basin of the filter until pure fuel
flows out.
Replace the fuel filter…every 400 hours.
1) Use proper container when venting the fuel to protect environment and secure safety. Do not
pour the fuel on ground、into slot or river、pool and lake. Properly dispose of the scrap fuel.
2) Clean the surrounding area of filter. Disassemble the filter, clean the surface of the sealed
washer.
3) Replace O ring.
4) Fill clean fuel into the new fuel filter and lubricate the O ring with clean oil.
5) Screw down the filter by your hands, but make sure not over do it.
6) Exhaust the air from fuel system after replacement of the filter.
Check the fuel hose…every day…every 200 hours
In order to prevent such danger:
1) Park the excavator on firm level ground. Lower the bucket to ground, stop the engine in a
correct manner, and take off the key from key switch.
2) Check the twist wear and leakage of fuel hose. Replace or fasten the hose if any abnormality
Over screwing will have the screw
thread distorted and damage the
sealed ring of filter core or filter
shell.
More operation details are on
chapter “ engine operation &
maintenance instruction book”