Chapter 2: Server Installation
23
Installing the Outer Rails on the Rack
Determine where you want to place the server in the rack (see the Rack and Server
Precautions in Section 2.2).
Note:
Use the procedure below to install the outer rails onto the rack.
Installing the Outer Rails (Figure 2-5)
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks of the front of the outer rail onto the slots on the front of the rack. If
necessary, use screws to secure the outer rails to the rack, as illustrated above.
4. 
rack.
5. Hang the hooks of the rear portion of the outer rail onto the slots on the rear of the rack.
If necessary, use screws to secure the rear of the outer rail to the rear of the rack.
6. Repeat steps 1-5 for the remaining outer rail.
Figure 2-5. Extending and Releasing the Outer Rails
21D01
L-min=676.00(26.61")(outer rail)
1
4
3
2