SuperServer 2029TP-HTR/HC1R/HC0R User's Manual
24
Figure 2-6. Installing the Server into a Rack
Ball-Bearing
Shuttle
Standard Chassis Installation
Installing the Chassis into a Rack (Figure 2-6)
1. 
2. 
3. Pull the middle rail out from the front of the outer rail and make sure that the ball-
bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure even on
both sides, until the locking tab of the inner rail clicks into the front of the middle rail,
locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis all the
way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles to the front
of the rack.