Chapter 1: Introduction
Power Supply Indicators
Power Supply Condition Green LED Amber LED
No AC Power to Power Supply OFF OFF
Power Supply critical events causing a shutdown/ failure/
OCP/ OVP/ Fan Fail/ OTP/ UVP
OFF Amber LED
Power Supply Warning Events Where the power supply
continues to operate; High temperature; Over voltage;
under voltage, etc.
OFF 1Hz Blink Amber
AC present only 12VSB ON (PS OFF) 1Hz Blink Green OFF
Output ON and OK Green OFF
AC cord unplugged and in redundant mode OFF Amber