46
i
EN
4.
Finally, dismantle the surface-
mounted belt winder as previously
demonstrated on page 45.
3.
Maintain pressure on the disengag-
ing bracket and pull the belt out of
the belt winder as far as possible.
19. Surface-mounted belt winder, remove the belt in the event of unit failure
In the event that the belt winder unit
fails and the motor no longer runs,
you can use the disengaging bracket
provided in order to fully remove
the belt from the belt winder unit,
without the need for cutting it. For
this, you must rst dismantle the
surface-mounted belt winder.
1.
Remove the mains adapter from
the socket.
2.
Release the drive using a sharp
object (e.g. a paper clip).
Drive release
Drive release
ATTENTION
Hold on to the belt tightly, as otherwise
the roller shutters may slam shut.
A small amount of resistance must be
overcome when pressing.
Release the belt from the fastening
hook and pull it out completely from
the belt winder.