9
i
EN
Exceeding the maximum permissible running time (KB) may overload and
damage the superrollo GW60.
◆ The maximum permissible running time for a cycle may not be exceeded when the
equipment is in operation. For this reason, the superrollo GW60 has an automatic
running time limit (KB) of ve minutes.
◆ If the running time limit is triggered, then the superrollo GW60 must be left for at
least 30 minutes to cool down. Full operational availability is re-established after
approx. one hour.
According to EN 13659, it is necessary to determine that the movement conditions for
the shutters are maintained in accordance with EN 12045.
◆ The displacement must be of at least 40 mm on the lower edge in the rolled-out
position with a force of 150 N in the upwards direction.
◆ In doing so, it must be ensured that the extending speed of the shutters for the
nal 0.4 m is less than 0.15 m/s.
4. Safety instructions
Sudden movement of the belt winder may lead to risk of injury.
◆ Only carry out the installation of the belt winder in an isolated, zero-volts state.
◆ Remove the power supply from the mains socket before carrying out any
maintenance, cleaning or repair work.