36
Appendix B. Data Frame Format of Continuous Sending [ASCII]
Field Name
Code
HEX
Description
Example
START [Byte1]
=
3D
=
Weighing State
[Byte2]
O
4F
Overload
S
S
53
Stable
M
4D
Motion
Data Name
[Byte3]
G
47
Gross Weight
N
N
4E
Net Weight
P
50
Net Weight Peak Value
B
42
Unused
T
54
Unused
D
44
Displayed Characters
U
55
Unused
Data
[9 Bytes]
Format A:
Weight Data
[Byte4~12]
+/-
2B/2D
Sign
+00123.4k
[DEC]
Weight Value
[7 Bytes]
30~39
2EH
0~9
Decimal Point ‘.’
Unit [1 Byte]:
(Space)
k
t
g
20
6B
74
67
Space: None
k: kg
Format B:
Displayed
Characters
[Byte4~12]
d
64
ID Code
d
Point Code
[1 Byte]
00~FF
BIT7=0: Unused
2. dISP
Highest
Bit’s Point:
ON
Point Code
=20H
BIT6=0: Unused
If BIT5=1:
Highest Bit’s Point: ON
If BIT4=1:
Bit5’s Point: ON
If BIT3=1:
Bit4’s Point: ON
If BIT2=1:
Bit3’s Point: ON
If BIT1=1:
Bit2’s Point: ON
If BIT0=1:
Lowest Bit’s Point: ON
Characters
[6 Bytes]
XX XX XX
XX XX XX
ACSII
d
64
ID Code
d
SUM Check [Byte13]
1 Byte
XX
SUM=Byte1+Byte2+…
+Byte12
END
[Byte14~15]
<CR>
<LF>
0D
0A
<CR>
<LF>