EasyManua.ls Logo

Supmeter BST106-B60S(L) - Appendix B. Data Frame Format of Continuous Sending [Ascii]

Supmeter BST106-B60S(L)
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Appendix B. Data Frame Format of Continuous Sending [ASCII]
Field Name
Code
HEX
Description
Example
START [Byte1]
=
3D
=
Weighing State
[Byte2]
O
4F
Overload
S
S
53
Stable
M
4D
Motion
Data Name
[Byte3]
G
47
Gross Weight
N
N
4E
Net Weight
P
50
Net Weight Peak Value
B
42
Unused
T
54
Unused
D
44
Displayed Characters
U
55
Unused
Data
[9 Bytes]
Format A:
Weight Data
[Byte4~12]
+/-
2B/2D
Sign
+00123.4k
[DEC]
Weight Value
[7 Bytes]
30~39
2EH
0~9
Decimal Point ‘.’
Unit [1 Byte]:
(Space)
k
t
g
20
6B
74
67
Space: None
k: kg
Format B:
Displayed
Characters
[Byte4~12]
d
64
ID Code
d
Point Code
[1 Byte]
00~FF
BIT7=0: Unused
2. dISP
Highest
Bits Point:
ON
Point Code
=20H
BIT6=0: Unused
If BIT5=1:
Highest Bits Point: ON
If BIT4=1:
Bit5s Point: ON
If BIT3=1:
Bit4s Point: ON
If BIT2=1:
Bit3s Point: ON
If BIT1=1:
Bit2s Point: ON
If BIT0=1:
Lowest Bits Point: ON
Characters
[6 Bytes]
XX XX XX
XX XX XX
ACSII
d
64
ID Code
d
SUM Check [Byte13]
1 Byte
XX
SUM=Byte1+Byte2+
+Byte12
END
[Byte14~15]
<CR>
<LF>
0D
0A
<CR>
<LF>

Related product manuals